Summary & Purpose

These files are sample needles analyzed via Local Electrode Atom Probe (LEAP) for the purpose of conducting cluster analysis to characterize nanoscale oxide phases.

Date of Publication or Submission

2017

DOI

https://doi.org/10.18122/B2GC7D

Funding Citation

This research was sponsored in part by the US Nuclear Regulatory Commission Grant NRC-HQ-84-14-G-0056, the Micron Foundation, and by the US DOE, Office of Nuclear Energy under DOE Idaho Operations Office Contract DE-AC07-05ID14517, as part of the Nuclear Science User Facilities experiments 13-419, 14-486, 15-540, 15-569, 16-625, and 16-710.

Single Dataset or Series?

Series

Data Format

.RHIT (raw LEAP data)

Data Attributes

Irradiation conducted at Michigan Ion Beam Laboratory (MIBL). Dose rate = 1.2 x 10^(-5) dpa/s. Atom probe tomography (APT) needles were fabricated using an FEI Quanta 3D FEG focused ion beam (FIB). Sample wedges ~2 μ wide and ~3 μ deep were cut and lifted in a direction perpendicular to the surface of the material. The wedges were subsequently mounted onto silicon posts and partitioned, resulting in 6-8 APT tips per specimen. The tips were then milled using annular ring patterns to shape them into needles with a tip radius = 50 nm Each needle was sharpened such that the tip of the needle was positioned just below the irradiated bulk surface. Each needle was analyzed with a Cameca LEAP 4000X HR at CAES, operated in laser pulsed mode with samples held at 40 K. Laser power ranged from 40-100 pJ, with a pulse repetition rate of 200 kHz.

Time Period

LEAP analysis conducted between 20141211-20141212

Privacy and Confidentiality Statement

Boise State University is explicitly compliant with federal and state laws surrounding data privacy including the protection of personal financial information through the Gramm-Leach-Bliley Act, personal medical information through HIPAA, HITECH and other regulations.

Use Restrictions

Users are free to share, copy, distribute and use the dataset; to create or produce works from the dataset; to adapt, modify, transform and build upon the dataset as long as the user attributes any public use of the dataset, or works produced from the dataset, referencing the author(s) and DOI link. For any use or redistribution of the dataset, or works produced from it, the user must make clear to others the license of the dataset and keep intact any notices on the original dataset. If users publicly use any adapted version of this dataset, or works produced from an adapted dataset, you must also offer that adapted database under this license. If users redistribute the dataset, or an adapted version of it, then users may use technological measures that restrict the work (such as DRM) as long as users also redistribute a version without such measures. This dataset may not be used for commercial purposes.

Disclaimer of Warranty

BOISE STATE UNIVERSITY MAKES NO REPRESENTATIONS ABOUT THE SUITABILITY OF THE INFORMATION CONTAINED IN OR PROVIDED AS PART OF THE SYSTEM FOR ANY PURPOSE. ALL SUCH INFORMATION IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. BOISE STATE UNIVERSITY HEREBY DISCLAIMS ALL WARRANTIES AND CONDITIONS WITH REGARD TO THIS INFORMATION, INCLUDING ALL WARRANTIES AND CONDITIONS OF MERCHANTABILITY, WHETHER EXPRESS, IMPLIED OR STATUTORY, FITNESS FOR A PARTICULAR PURPOSE, TITLE AND NON-INFRINGEMENT. IN NO EVENT SHALL BOISE STATE UNIVERSITY BE LIABLE FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF INFORMATION AVAILABLE FROM THE SYSTEM. THE INFORMATION PROVIDED BY THE SYSTEM COULD INCLUDE TECHNICAL INACCURACIES OR TYPOGRAPHICAL ERRORS. CHANGES ARE PERIODICALLY ADDED TO THE INFORMATION HEREIN. COMPANY AND/OR ITS RESPECTIVE SUPPLIERS MAY MAKE IMPROVEMENTS AND/OR CHANGES IN THE PRODUCT(S) AND/OR THE PROGRAM(S) DESCRIBED HEREIN AT ANY TIME, WITH OR WITHOUT NOTICE TO YOU. BOISE STATE UNIVERSITY DOES NOT MAKE ANY ASSURANCES WITH REGARD TO THE ACCURACY OF THE RESULTS OR OUTPUT THAT DERIVES FROM USE OF THE SYSTEM.