Effects of 14 MeV Neutron Irradiation on the DC Characteristics of CBRAM Cells

Document Type

Conference Proceeding

Publication Date

2016

DOI

http://dx.doi.org/10.1109/RADECS.2016.8093120

Abstract

CBRAM cells were irradiated with 14 MeV neutrons to a total fluence of 3.19×1013 n/cm2. This is the first time that the effect of displacement damage on the DC characteristics of CBRAM has been examined. The high resistance and low resistance states of the cells are shown to converge with increasing neutron fluence. After reaching a fluence of 2.93×1013 n/cm2, the CBRAM cells became irrecoverably locked into their final resistance state.

Comments

For a complete list of authors, please see article.

Share

COinS